FHIR © HL7.org  |  Server Home  |  FHIR Server FHIR Server 3.4.11  |  FHIR Version n/a  User: [n/a]

Resource StructureDefinition/FHIR Server from package kvdigital.terminsynchronisation-tvs#1.0.0-beta (47 ms)

Package kvdigital.terminsynchronisation-tvs
Type StructureDefinition
Id Id
FHIR Version R4
Source https://simplifier.net/resolve?scope=kvdigital.terminsynchronisation-tvs@1.0.0-beta&canonical=https://fhir.kbv.de/StructureDefinition/KBV_PR_116117_TERMINSERVICE_TVS_TERMINSYNCHRONISATION_Bundle_Batch_Request
Url https://fhir.kbv.de/StructureDefinition/KBV_PR_116117_TERMINSERVICE_TVS_TERMINSYNCHRONISATION_Bundle_Batch_Request
Version 0.2.0
Status draft
Name KBV_PR_116117_TERMINSERVICE_TVS_TERMINSYNCHRONISATION_Bundle_Batch_Request
Title KBV_PR_116117_TERMINSERVICE_TVS_TERMINSYNCHRONISATION_Bundle_Batch_Request
Experimental False
Authority hl7
Description Das Bundle stellt die Möglichkeit zur Verfügung, mehrere Terminslots über einen Request zu löschen oder anzulegen.
Copyright Im folgenden Profil können Codes aus den Code-Systemen SNOMED CT®, LOINC, Ucum, ATC, ICD-10-GM, ICD-10-WHO, OPS, Alpha-ID/Alpha-ID-SE und ICF enthalten sein, die dem folgenden Urheberrecht unterliegen: This material includes SNOMED CT® Clinical Terms® (SNOMED CT® CT®) which is used by permission of SNOMED CT® International. All rights reserved. SNOMED CT® CT®, was originally created by The College of American Pathologists. SNOMED CT® and SNOMED CT® CT are registered trademarks of SNOMED CT® International. Implementers of these artefacts must have the appropriate SNOMED CT® CT Affiliate license. This material contains content from LOINC (http://LOINC.org). LOINC is copyright © 1995-2020, Regenstrief Institute, Inc. and the Logical Observation Identifiers Names and Codes (LOINC) Committee and is available at no cost under the license at http://LOINC.org/license. LOINC® is a registered United States trademark of Regenstrief Institute, Inc. This product includes all or a portion of the UCUM table, UCUM codes, and UCUM definitions or is derived from it, subject to a license from Regenstrief Institute, Inc. and The UCUM Organization. Your use of the UCUM table, UCUM codes, UCUM definitions also is subject to this license, a copy of which is available at http://unitsofmeasure.org. The current complete UCUM table, UCUM Specification are available for download at http://unitsofmeasure.org. The UCUM table and UCUM codes are copyright © 1995-2009, Regenstrief Institute, Inc. and the Unified Codes for Units of Measures (UCUM) Organization. All rights reserved. THE UCUM TABLE (IN ALL FORMATS), UCUM DEFINITIONS, AND SPECIFICATION ARE PROVIDED 'AS IS.' ANY EXPRESS OR IMPLIED WARRANTIES ARE DISCLAIMED, INCLUDING, BUT NOT LIMITED TO, THE IMPLIED WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE. Dieses Material enthält Inhalte aus ATC. Die Erstellung erfolgte unter Verwendung der Datenträger der amtlichen Fassung der ATCKlassifikation mit DDD des Bundesinstituts für Arzneimittel und Medizinprodukte (BfArM). Dieses Material enthält Inhalte aus ICD-10-GM, ICD-10-WHO, OPS Alpha-ID ans Alpha-ID-SE. Die Erstellung erfolgt unter Verwendung der maschinenlesbaren Fassung des Bundesinstituts für Arzneimittel und Medizinprodukte (BfArM). Dieses Material enthält Inhalte aus ICF. Die Erstellung erfolgt unter Verwendung der maschinenlesbaren Fassung des Deutschen Instituts für Medizinische Dokumentation und Information (DIMDI). ICF-Kodes, -Begriffe und -Texte © Weltgesundheitsorganisation, übersetzt und herausgegeben durch das Deutsche Institut für Medizinische Dokumentation und Information von der International classification of functioning, disability and health - ICF, herausgegeben durch die Weltgesundheitsorganisation.
Type Bundle
Kind resource

Resources that use this resource

No resources found


Resources that this resource uses

StructureDefinition
https://fhir.kbv.de/StructureDefinition/KBV_PR_116117_TERMINSERVICE_TVS_TERMINSYNCHRONISATION_Slot KBV_PR_116117_TERMINSERVICE_TVS_TERMINSYNCHRONISATION_Slot
https://fhir.kbv.de/ValueSet/KBV_VS_116117_TERMINSERVICE_TVS_TERMINSYNCHRONISATION_Batch_Http_Methods KBV_VS_116117_TERMINSERVICE_TVS_TERMINSYNCHRONISATION_Batch_Http_Methods


Narrative

Note: links and images are rebased to the (stated) source

Das Bundle stellt die Moeglichkeit zur Verfuegung, mehrere Terminslots ueber einen Request zu loeschen oder anzulegen.

Source

{
  "resourceType" : "StructureDefinition",
  "id" : "KBV-PR-116117-TERMINSERVICE-TVS-TSYNCH-Bundle-Batch-Request",
  "text" : {
    "status" : "generated",
    "div" : "<div xmlns=\"http://www.w3.org/1999/xhtml\">Das Bundle stellt die Moeglichkeit zur Verfuegung, mehrere Terminslots ueber einen Request zu loeschen oder anzulegen.</div>"
  },
  "url" : "https://fhir.kbv.de/StructureDefinition/KBV_PR_116117_TERMINSERVICE_TVS_TERMINSYNCHRONISATION_Bundle_Batch_Request",
  "version" : "0.2.0",
  "name" : "KBV_PR_116117_TERMINSERVICE_TVS_TERMINSYNCHRONISATION_Bundle_Batch_Request",
  "title" : "KBV_PR_116117_TERMINSERVICE_TVS_TERMINSYNCHRONISATION_Bundle_Batch_Request",
  "status" : "draft",
  "publisher" : "kv.digital GmbH",
  "contact" : [
    {
      "name" : "kv.digital GmbH",
      "telecom" : [
        {
          "system" : "url",
          "value" : "https://www.kv.digital"
        }
      ]
    }
  ],
  "description" : "Das Bundle stellt die Möglichkeit zur Verfügung, mehrere Terminslots über einen Request zu löschen oder anzulegen.",
  "copyright" : "Im folgenden Profil können Codes aus den Code-Systemen SNOMED CT®, LOINC, Ucum, ATC, ICD-10-GM, ICD-10-WHO, OPS, Alpha-ID/Alpha-ID-SE und ICF enthalten sein, die dem folgenden Urheberrecht unterliegen: This material includes SNOMED CT® Clinical Terms® (SNOMED CT® CT®) which is used by permission of SNOMED CT® International. All rights reserved. SNOMED CT® CT®, was originally created by The College of American Pathologists. SNOMED CT® and SNOMED CT® CT are registered trademarks of SNOMED CT® International. Implementers of these artefacts must have the appropriate SNOMED CT® CT Affiliate license. This material contains content from LOINC (http://LOINC.org). LOINC is copyright © 1995-2020, Regenstrief Institute, Inc. and the Logical Observation Identifiers Names and Codes (LOINC) Committee and is available at no cost under the license at http://LOINC.org/license. LOINC® is a registered United States trademark of Regenstrief Institute, Inc. This product includes all or a portion of the UCUM table, UCUM codes, and UCUM definitions or is derived from it, subject to a license from Regenstrief Institute, Inc. and The UCUM Organization. Your use of the UCUM table, UCUM codes, UCUM definitions also is subject to this license, a copy of which is available at http://unitsofmeasure.org. The current complete UCUM table, UCUM Specification are available for download at http://unitsofmeasure.org. The UCUM table and UCUM codes are copyright © 1995-2009, Regenstrief Institute, Inc. and the Unified Codes for Units of Measures (UCUM) Organization. All rights reserved. THE UCUM TABLE (IN ALL FORMATS), UCUM DEFINITIONS, AND SPECIFICATION ARE PROVIDED 'AS IS.' ANY EXPRESS OR IMPLIED WARRANTIES ARE DISCLAIMED, INCLUDING, BUT NOT LIMITED TO, THE IMPLIED WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE. Dieses Material enthält Inhalte aus ATC. Die Erstellung erfolgte unter Verwendung der Datenträger der amtlichen Fassung der ATCKlassifikation mit DDD des Bundesinstituts für Arzneimittel und Medizinprodukte (BfArM). Dieses Material enthält Inhalte aus ICD-10-GM, ICD-10-WHO, OPS Alpha-ID ans Alpha-ID-SE. Die Erstellung erfolgt unter Verwendung der maschinenlesbaren Fassung des Bundesinstituts für Arzneimittel und Medizinprodukte (BfArM). Dieses Material enthält Inhalte aus ICF. Die Erstellung erfolgt unter Verwendung der maschinenlesbaren Fassung des Deutschen Instituts für Medizinische Dokumentation und Information (DIMDI). ICF-Kodes, -Begriffe und -Texte © Weltgesundheitsorganisation, übersetzt und herausgegeben durch das Deutsche Institut für Medizinische Dokumentation und Information von der International classification of functioning, disability and health - ICF, herausgegeben durch die Weltgesundheitsorganisation.",
  "fhirVersion" : "4.0.1",
  "kind" : "resource",
  "abstract" : false,
  "type" : "Bundle",
  "baseDefinition" : "http://hl7.org/fhir/StructureDefinition/Bundle",
  "derivation" : "constraint",
  "differential" : {
    "element" : [
      {
        "id" : "Bundle",
        "path" : "Bundle",
        "short" : "Batch Request Bundle",
        "definition" : "Das Bundle stellt die Möglichkeit zur Verfügung, mehrere Terminslots über einen Request zu löschen oder anzulegen."
      },
      {
        "id" : "Bundle.meta",
        "path" : "Bundle.meta",
        "min" : 1
      },
      {
        "id" : "Bundle.meta.profile",
        "path" : "Bundle.meta.profile",
        "slicing" : {
          "discriminator" : [
            {
              "type" : "value",
              "path" : "$this"
            }
          ],
          "rules" : "open"
        },
        "min" : 1
      },
      {
        "id" : "Bundle.meta.profile:kvdigitalProfil",
        "path" : "Bundle.meta.profile",
        "sliceName" : "kvdigitalProfil",
        "min" : 1,
        "max" : "1",
        "patternCanonical" : "https://fhir.kbv.de/StructureDefinition/KBV_PR_116117_TERMINSERVICE_TVS_TERMINSYNCHRONISATION_Bundle_Batch_Request|0.2.0"
      },
      {
        "id" : "Bundle.type",
        "path" : "Bundle.type",
        "fixedCode" : "batch",
        "mustSupport" : true
      },
      {
        "id" : "Bundle.entry",
        "path" : "Bundle.entry",
        "short" : "Requests",
        "definition" : "Requests, die nacheinander als batch ausgeführt werden sollen",
        "min" : 1,
        "mustSupport" : true
      },
      {
        "id" : "Bundle.entry.resource",
        "path" : "Bundle.entry.resource",
        "type" : [
          {
            "code" : "Resource",
            "profile" : [
              "https://fhir.kbv.de/StructureDefinition/KBV_PR_116117_TERMINSERVICE_TVS_TERMINSYNCHRONISATION_Slot"
            ]
          }
        ],
        "mustSupport" : true
      },
      {
        "id" : "Bundle.entry.request",
        "path" : "Bundle.entry.request",
        "short" : "Details zum Request",
        "definition" : "Details zu einem einzelnen Request",
        "min" : 1,
        "constraint" : [
          {
            "key" : "regex-1",
            "severity" : "error",
            "human" : "Enforce format \"Slot\" for POST requests",
            "expression" : "method = 'POST' implies url = 'Slot'"
          },
          {
            "key" : "regex-2",
            "severity" : "error",
            "human" : "Enforce format \"Slot/[uuid]\" for DELETE requests",
            "expression" : "method = 'DELETE' implies url.matches('Slot/[0-9a-f]{8}-[0-9a-f]{4}-[0-9a-f]{4}-[0-9a-f]{4}-[0-9a-f]{12}')"
          },
          {
            "key" : "ifMatch",
            "severity" : "error",
            "human" : "ifMatch only for DELETE requests",
            "expression" : "ifMatch.empty() or (method = 'DELETE')"
          }
        ],
        "mustSupport" : true
      },
      {
        "id" : "Bundle.entry.request.method",
        "path" : "Bundle.entry.request.method",
        "short" : "POST | DELETE",
        "mustSupport" : true,
        "binding" : {
          "strength" : "required",
          "valueSet" : "https://fhir.kbv.de/ValueSet/KBV_VS_116117_TERMINSERVICE_TVS_TERMINSYNCHRONISATION_Batch_Http_Methods"
        }
      },
      {
        "id" : "Bundle.entry.request.url",
        "path" : "Bundle.entry.request.url",
        "short" : "URL für den Request",
        "example" : [
          {
            "label" : "create request",
            "valueUri" : "Slot"
          },
          {
            "label" : "delete request",
            "valueUri" : "Slot/b0481afd-281b-4f62-8255-da0af95087xx"
          }
        ],
        "mustSupport" : true
      },
      {
        "id" : "Bundle.entry.request.ifMatch",
        "path" : "Bundle.entry.request.ifMatch",
        "short" : "Version des Terminslots",
        "definition" : "Die Angabe der Version des Terminslots stellt sicher, dass die aktuellste Version des Slots bekannt ist, bevor dieser geändert wird.",
        "comment" : "Die versionId des Terminslots muss nur bei einem DELETE-Request angegeben werden.",
        "mustSupport" : true
      }
    ]
  }
}

XIG built as of ??metadata-date??. Found ??metadata-resources?? resources in ??metadata-packages?? packages.